Product description
24 V DC to 230 V AC / 60 Hz inverter with 5 kVA (P30), designed to work in demanding conditions. It offers 4 kW continuous at 40 °C, peaks of 9 kW, an efficiency of 92 % and galvanic isolation to protect sensitive equipment and guarantee a stable supply.
The Mass Sine 24/5000 is designed to power complex loads on board or in mobile and fixed applications. Its high-frequency technology and pure sine wave combine to eliminate humming, improve efficiency and prevent tripping or damage to delicate electronics. It includes an automatic saving mode to extend battery autonomy without affecting low-consumption loads and can be integrated into MasterBus networks to centralise control via remote panel or EasyView display (with MasterBus interface). Professional connections and compatibility with Masterswitch/Systemswitch help to automatically manage the available power source (mains, generator or inverter).
Key features
- Pure sine wave 230 V / 60 Hz to protect sensitive equipment.
- Power P30 5 kW and 4 kW continuous at 40 °C to sustain high consumption.
- Peak 9 kW to start loads with high inrush current.
- Efficiency of 92 % and economy mode to maximise the available energy.
- Galvanic isolation and typical THD < 5 % to improve supply quality.
- MasterBus integration (via interface) to monitor and control the inverter from a single system.
- Compatibility with Masterswitch/Systemswitch to select and switch power sources.
- Protections: battery undervoltage/overvoltage, overtemperature, overload and short circuit.
- Robust design: full-load operation up to 40 °C (with derating above) and ambient range −25 to 80 °C.
Key specifications
| Parameter | Value |
|---|---|
| Input (battery) | 24 V DC; recommended capacity > 400 Ah |
| Output | 230 V AC / 60 Hz (±0.01 Hz); pure sine wave; accepts any cos φ |
| Power | P30 5000 W @ 40 °C; continuous 4000 W @ 40 °C; peak 9000 W |
| Efficiency | 92 %; typical THD < 5 % |
| No-load consumption | ≤6 W (ON) / ≤1.2 W (saving mode) to reduce consumption at rest |
| Galvanic isolation | Yes (isolated AC output) |
| Battery thresholds | Low cut-off 19 V / reconnection 22 V; high cut-off 32 V / reconnection 30 V |
| Input current at nominal load | ≤230 A; max. DC ripple 5 % RMS |
| Electrical protection | IP23; natural/forced cooling |
| Fuses and wiring | Minimum 1 × 250 A (slow) or 2 × 125 A; minimum cross-section 2 × 70 mm² |
| Dimensions (H × W × D) | 470 × 315 × 254 mm; weight 19 kg |
| Indicators and control | Front LEDs; remote control C4-RI / EasyView 5 via MasterBus |
| Compliance | CE, E-mark, ABYC A-31 |