● The push button marked "Valve" will manually actuate a remote solenoid operated gas valve, if this is installed in the system. If this solenoid valve is in the open position (or not fitted), the presence of gas is detected continuously. If the valve is closed, detection will take place intermittently. Please note, the valve itself is not supplied with the gas detector.
● If the gas detector senses high concentrations of flammable gases and/or carbon monoxide, it will trigger an acoustic alarm and an LED on the control panel. Petrol fumes can trigger the alarm at extremely low concentrations, which makes this device less suitable for boats with petrol engine(s).
● The "Mute" button will silence the alarm. The gas detector is provided with three switched connections rated at 1A each. In the event of an alarm situation, these will actuate (if fitted), an extraction ventilator, an external alarm or horn and a solenoid operated gas valve. The extraction ventilator can also be operated manually by means of the "Fan" button.
● Should the supply voltage drop too low, an acoustic alarm will be triggered and the LED on the control panel will flash. A test function confirms the correct functioning of the gas sensor(s), as well as the three switched connections for the ventilator, external alarm and gas valve. An LED on the sensor indicates when it has reached it's maximum life span and should be replaced.
● Voltage: 12 or 24V DC.
● Control panel dimensions: 85 x 85mm.
● Build in depth: 40mm.
● Sensor dimensions: 35 x 26 x 62mm (high)
● Maximum current that can be supplied via relay for: extractor, gas solenoid valve and external alarm 1 A for each function