Skip to content
I have bought other times here
I'm already a customer
I want to register
New customer
By creating an account at francobordo.com you can make your purchases quickly in our virtual store, check the status of your orders and check your previous operations.

Ahead! We were waiting for you.
Create an Account
Access the
Professionals Area

Register and take advantage of the discounts and advantages of being a Professional of Nautical

Join the more than 500 Nautical Professionals now

professional register
Black Friday · Easysea & Garmin
Victron Energy Combiner Isolator Cyrix-ct
Victron Energy Combiner Isolator Cyrix-ct
Victron Energy Combiner Isolator Cyrix-ct
Victron Energy Combiner Isolator Cyrix-ct
Victron Energy Combiner Isolator Cyrix-ct

Victron Energy Combiner Isolator Cyrix-ct

Ref.: CYR010120011R

Choose option:

67,90 €
VAT included
Select an option to see availability

Product description

The Cyrix battery combiner is a microprocessor-controlled heavy-duty relay that automatically connects batteries in parallel when one of them has reached a pre-set voltage (indicating that the battery is being charged), and disconnects them when the voltage drops below the float level (indicating that one or more batteries are being discharged). Cyrix battery combiners are an excellent substitute for diode splitters: the main feature is that there is virtually no voltage loss, so the output voltage of alternators or battery chargers does not need to be increased.

Features

Intelligent battery monitoring to prevent unwanted switching

Some battery combiners (also called voltage-controlled relays, or split charge relays) will disconnect a battery in the event of a short but high amperage load. A battery combiner may also fail to connect a large but discharged battery bank because the DC voltage immediately drops below the disengage value when the batteries are connected.

The Cyrix-ct 12/24 software does more than simply connect and disconnect on the basis of battery voltage and a fixed time delay. The Cyrix-ct 12/24 checks the general trend (increasing or decreasing voltage) and reverses a previous action only if the trend has reversed during a certain period of time. The time span depends on how far the voltage deviates from that trend (for battery combiners with multiple engage/disengage profiles, see the Cyrix-i 400A).

12/24 V self-regulating and without voltage loss

The Cyrix-ct 12/24 automatically detects the system voltage.

Cyrix battery combiners are an excellent substitute for diode splitters. The main feature is that there is virtually no voltage loss, so the output voltage of alternators or battery chargers does not need to be increased.

Long bolts allow more than one power cable to be connected

Cyrix 12/24-120: 13 mm (M6)
Cyrix 12/24-230: 16 mm (M8)

Overheating protection (due to prolonged overload, for example)

The Cyrix will deactivate in the event of excessive contact temperature, and will reactivate once it has cooled down.

LED status indicator (Cyrix 12/24 230 only)

  • LED on: activated
  • LED flash of 10 s: deactivated
  • LED flash of 2 s: connecting
  • LED blinking of 2 s: disconnecting
  • LED blinking of 0.25 s: alarm (overtemperature; voltage > 16 V; both batteries < 10 V; one battery < 2 V)

(multiply by two for 24 V)

Priority for the starter battery

In a standard set-up, the alternator is connected directly to the starter battery. The service battery, and possibly also the bow thruster and other batteries, are each connected to the starter battery with Cyrix combiners. When the Cyrix detects that the starter battery has reached the engage voltage, it will activate to allow the other batteries to be charged in parallel.

Voltage sensing and bidirectional power supply from both batteries

The Cyrix detects the voltage of both connected batteries. It will therefore also activate if, for example, the service battery is being charged by a battery charger.

The Cyrix-ct 12/24 has a dual power supply. It will therefore also disconnect if the battery voltage is too low to operate the Cyrix.

To prevent it from operating unexpectedly during installation, or when a battery is disconnected, the Cyrix-i 12/24-100 will not close if the voltage of one of the two connected batteries is below 2 V (12 V battery) or 4 V (24 V battery).

Parallel connection in an emergency (StartAssist)

The Cyrix can also be activated by means of a push button (the Cyrix remains engaged for 30 s) or by means of a switch to connect batteries in parallel manually.

This is especially useful in an emergency, when the starter battery is discharged or damaged.